4 printouts, 5 output format – Rice Lake Ranger Count 3000 Series, Ohaus User Manual

Page 35

Advertising
background image

Ranger™ Count 3000 Series EN-33

7.4 Printouts

The following sample print outs are generated by the Print button, “P” Command or alternate

print command. The content of the printout is defined in the Print Content menu item. A

maximum of 24 characters can be printed on each line.

Description

Comment

PN: 123456789926

Part Number line

If Printx  Content  P/N is ON

363 PCS NET

Result line

If Printx  Content  Result is ON

0.1420 kg G

Gross value line

If Printx  Content  Gross is ON and a tare value is entered

0.0420 kg NET

Net value line

If Printx  Content  Net is ON and a tare value is entered

0.1000 kg PT

Tare value line

If Printx  Content  Tare is ON and a tare value is entered

APW: 0.11500 g

APW line

If Printx  Content  APW is ON

N: 3

Accumulation line

If Printx  Content  Accu is All

ACC: 956 Pcs

Accumulation line

If Printx  Content  Accu is All


7.5 Output Format

Weight string print format:
Field

Weight space Unit

space Stability space G/N

Space Term.

Char(s)

Length 9

1

5

1

1

1

NET

1


Each field is followed by a single delimiting space (ASCII: 32)

Definitions:
Weight

- Up to 9 characters, right justified, - at immediate left of most significant character

(if negative).

Unit

- Up to 5 characters, left justified. If the Unit in the Print Content menu was set to

OFF, the unit will be removed in the weight string and replaced by spaces.

Stability

- “?” character is printed if not stable. If weight is stable neither “?” or following

space is printed.

G/N

- “NET” printed if weight is net weight, ‘G’ or nothing printed if weight is a gross

weight.

Terminating Character(s) - terminating character(s) printed depending on FEED menu setting.