Series – Rice Lake Ranger Count 3000 Series, Ohaus User Manual
Page 18
EN-16
Ranger™ Count 3000
Series
Auto Tare
[A.tArE]
Set the automatic tare functionality.
OFF
= Automatic Tare is disabled
ON
= the first stable gross weight is tared
ON-ACC = stable gross loads within the accept limits are tared (in Check weighing mode)
Beeper Opt [bp.OPt]
Set whether or not the beeper sounds when APW has been optimized.
OFF
= disabled
ON
= enabled
Beeper Signal
[Bp.sIG]
Set how the beeper responds in Check Weighing mode.
OFF
= the beeper is disabled
ACCEPT = the beeper will sound when the weight is within the Accept range.
UNDER = the beeper will sound when the weight is below the Under setting.
OVER = the beeper will sound when the weight is above the Over setting.
OVER-
UNDER = the beeper will sound when the weight is below the Under setting or above the
Over setting.
Beeper Key
[BP.key]
Set whether the beeper sounds when a button is pressed.
OFF
= disabled
ON
= enabled
Accumulation
[aCCUmM]
Set the accumulation functionality.
OFF
= accumulation disabled
AUTO = automatic accumulation
MAN
= manual accumulation
End Setup
[End]
Advance to the next menu or return to the top of the current menu.