Series – Rice Lake Ranger Count 3000 Series, Ohaus User Manual

Page 18

Advertising
background image

EN-16

Ranger™ Count 3000

Series

Auto Tare

[A.tArE]

Set the automatic tare functionality.

OFF

= Automatic Tare is disabled

ON

= the first stable gross weight is tared

ON-ACC = stable gross loads within the accept limits are tared (in Check weighing mode)

Beeper Opt [bp.OPt]

Set whether or not the beeper sounds when APW has been optimized.

OFF

= disabled

ON

= enabled

Beeper Signal

[Bp.sIG]

Set how the beeper responds in Check Weighing mode.

OFF

= the beeper is disabled

ACCEPT = the beeper will sound when the weight is within the Accept range.

UNDER = the beeper will sound when the weight is below the Under setting.

OVER = the beeper will sound when the weight is above the Over setting.

OVER-

UNDER = the beeper will sound when the weight is below the Under setting or above the

Over setting.

Beeper Key

[BP.key]

Set whether the beeper sounds when a button is pressed.

OFF

= disabled

ON

= enabled

Accumulation

[aCCUmM]

Set the accumulation functionality.

OFF

= accumulation disabled

AUTO = automatic accumulation

MAN

= manual accumulation


End Setup

[End]

Advance to the next menu or return to the top of the current menu.