5 installing transient protection, Junction box ground wire connections, Connecting electronic equipment 25 – Rice Lake SURVIVOR OTR Steel Deck User Manual

Page 29: 32 1 on

Advertising
background image

Connecting Electronic Equipment

25

7.5

Installing Transient Protection

A lightning protection package comes standard on all truck scales. The individual components of this
comprehensive package are designed to protect AC and DC portions of the system. The lightning protection
package includes:

DC transient protection included with standard J-box board(s). This DC transient protection handles up to
eight load cells. Scales with more than eight load cells require additional J-boxes.

Self-contained DC transient protection unit in the homerun cable at the indicator.

115 VAC uninterruptable power supply/surge protector in the AC line before the indicator.

Number 10 bare ground conductor cable buried in earth from scale frame to DC transient board at indicator
and finally to the AC power ground lug.

Figure 7-4. Grounding and Transient Protection on OTR Scale

Serial communications (if used) may also require transient protection to fully protect entire system. A TP-232
DC Transient Protection is suitable protection for serial communications lines. In addition, printers, remote
displays, and other devices connected to serial communications should be protected with AC transient
protection.

21306 REV. B

-SI

+SI

+SE

JU5

JU6

JU7

JU8

JU9

JU10

JU11

JU12

TRIM 8

TRIM 7

TRIM 6

TRIM 5

TRIM 4

TRIM 3

TRIM 2

-SE

SHD

+EX

-EX

CELL 2

CELL 8

CELL 7

CELL 6

CELL 5

CELL 4

CELL 3

CELL 1

INDICATO

R

TRIM 1

PT8

PT7

PT6

PT5

PT4

PT3

PT2

PT1

RNET2

RNET1

RNET3

RNET4

PT10

SECTION 3 TRI

M

3

2

1

ON

SECTION 2 TRIM

3

2

1

ON

PT10

PT9

SECTION 1 TRIM

3

2

1

ON

SECTION 4 TRIM

3

2

1

ON

PT12

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

+EXC

-EXC

+SIG

-SIG

SHD

Ground Wire

Junction Box Ground Wire Connections

Ground Lug

J-Box

Mounting

Stud

The scale frame must be connected with 10
ga. wire to the ground lug of the transient
protection board inside the junction box.

Scales with more than one junction box require ground
straps to be installed between modules. In addition, all
junction boxes need to be connected to the scale frame.

Final ground wire connection must be at AC power
supply ground terminal or ground rod.