Each step is split into 5 segments:

1. Outputs

2. Special Functions

3. End of Step

4. Others

5. Motor

4.7.1

Outputs

The outputs are fairly self explanatory. When a particular output is turned on, that function is
activated. Each relay output can be turned off or on by double clicking in the cell, or by pressing
the spacebar when the cell is highlighted.

4.7.2

Special Functions

Heating, Fill to temperature, and Cooldown are controlled by this section. Double clicking a func-
tion enables that function. When activated, each item will open a dialog box which asks for pa-
rameters necessary for the activation of the function.

4.7.3

End of Step

Each step must have an end step condition – this is the condition to be met, indicating that the step
is complete. Level and Temperature require a Watchdog time to be entered (typically 9 minutes for
Level and 15 minutes for Temperature). The Time end step condition will automatically end when
the time elapses, eliminating the need for a Watchdog. To edit or enable an end of step condition,
double click. A dialog box will appear, allowing to to change or enter a value.

4.7.4

Others

The Cooldown level and Temperature setpoint fields are indicators only - these fields will be blank
unless one selects the Cooldown function or the Heating function.

4.7.5

Motor

The motor segment indicates which motor profile and RPM (speed) will be used. Refer to the
water level chart, figure 4.4 on page 23 and the RPM chart shown in table 4.1 on page 24 for
details on the correct setting for the particular machine being programmed. Double clicking the
field will cause a dialog box to appear so that the correct value can be chosen.