or another cycle in the program group. Right click, and select Paste step from the sub-menu. Just
as with the Insert Step function, all existing steps shift one column to the right and that the pasted
step has replaced the previously highlighted step.

4.11

Enabling/Disabling Cells

In order to change the function of a step type, the existing end step function must be disabled
before the new condition can be enabled. The EL6 allows only one end step condition per step.
To disable a field, click the cell to select it. Then right click the cell and select Disable field from
the sub-menu. Now a different end step condition can be selected. If moving from a level or
temperature based step to a timed step, the watchdog timer must also be disabled. The motor
mode and RPM fields can also be disabled if no cylinder rotation is desired (Still fill for example).

4.12

Special Functions

4.12.1

Cooldown

The cooldown function can be used to cool the laundered goods to a particular temperature. En-
abling the cooldown function will display the sub-menu shown in figure 4.6 on page 26. Enter the
minimum water level (in cm of water), the maximum water level (in cm of water), the desired tem-
perature (in degrees Celsius), and the allowed time. The EL6 will alternate between draining and
filling of the machine in order to reach the desired temperature while maintaining the minimum
and maximum level parameters given a particular time.

Figure 4.6: Cooldown Dialog

26