Fill to temperature, Heating, 2 fill to temperature – B&C Technologies EL-6 Windows User Manual

Page 30: 3 heating

Advertising
background image

4.12.2

Fill to Temperature

The Fill to Temperature function is used to fill the machine to a temperature between the incoming
cold and hot water supply lines. Enabling the Fill to Temperature function will display the sub-
menu shown in figure 4.7 on page 27. Enter the water level (in cm of water), desired temperature
(in degrees Celsius), and the allowed time. The EL6 will modulate the cold water and hot water
valves to maintain the programmed temperature to the given level in the alloted time.

Figure 4.7: Fill to Temperature Dialog

4.12.3

Heating

The heating function controls the auxiliary heating system optionally installed (typically steam or
electric heating). Enter the desired temperature (in degrees Celsius). The EL6 will regulate the
temperature within 3 degrees Celsius (adjustable – see the maintenance functions section on page
35). Enabling the Heating function will display the sub-menu shown in figure 4.8 on page 27.

Figure 4.8: Heating Dialog

27