Motor Modes

Motor Modes are used to set the agitation profile for each step. There are 5 stock motor modes
used:

• Mode 1 – Standard wash agitation: 16 seconds forward, 4 seconds pause, 16 seconds reverse

• Mode 2 – Gentle wash agitation: 4 seconds forward, 16 seconds pause, 4 seconds reverse

• Mode 3 – Soak agitation: 5 seconds forward, 115 seconds pause, 5 seconds reverse

• Mode 14 – Reverse only: Used in the rebalancing function after an unbalance condition.

• Mode 15 – Forward only: Used in extract cycles

Figure 5.1: Motor Mode Area

To customize or add a new motor mode, simply double click in the field you wish to adjust. Refer
to figure 5.1 on page 30. When the sub-menu appears, change the seconds value to fit the process.
Any value between 1 and 240 seconds may be entered.