B&C Technologies EL-6 Windows User Manual

Page 39

Advertising
background image

• Number of outputs

Displays the EL6 configuration. Should ALWAYS say 24. Anything else and your programs
WILL BE CORRUPTED

. Recovery is possible, but embarrassing for the poor soul that makes

this error. Read only.

• Total Programs

The total number of programs this EL6 control has executed, not including partial programs.
Take care when transferring programs to a machine in use. If the stock programs are trans-
ferred to the machine, this counter will be overwritten. If making changes, it is best practice
to transfer the program set from the machine to the laptop, make the appropriate changes,
and finally transfer the programs back to the control. This keeps all counters in order in the
event that the owner/operator is making use of the program tracking features of the EL6.
Read only.

• Partial Programs

The total number of interrupted programs, caused by stopping the program before comple-
tion or possibly an out of balance condition. Read only.

• Working hours

The number of hours the control has spent executing wash programs. Does not include idle
time. Read only.

• Language

Selects from amongst 5 the languages the EL6 can display.

• Temperature

Select to display temperature in degrees Fahrenheit or degrees Celsius. Note: programing is
still done in degrees Celsius.

• Maximum level

Do not change - overflow and water waste will occur if levels too high for the machine are
programmed.

• Minimum level

Should never need changing. Leave at 10cm.

• Advance enable

Unchecking the box disables the advance button on the EL6 keypad.

• Machine enable

Unchecking the box will cause the EL6 to display an exclamation point (!) upon power cycle.
Very likely to confuse the operator and/or make the operator think the control is damaged.

• Spin safety time

Do not adjust! Really. Do not adjust!

36