Axesstel PST User Manual

Page 101

Advertising
background image

AXESSTEL Software User's Guide

Contents

phone. The data file is treated as binary, and no translation is

applied to its contents. Any data returned by the phone is displayed

in the scripting window in HEX and ASCII.

Syntax

send_data_file

“file_name

SEQ_NUMS

Requests that packets be sent with sequence numbers included.

Syntax

seq_nums

SER_REPORT

Reports the Symbol Error Rate (SER) counts, but does not reset them.

Syntax

ser_report

Example

ser_report

Script Command List

Response

Polls the subscriber station for current SER statistics, without

resetting the counters.

SER_RESET

Resets the Symbol Error Rate (SER) statistics.

Syntax

ser_reset

Example

ser_reset

Response

Resets the SER counters.

SET ATTN (analog test command)

Sets the analog power control to a specific value (range 07).

Syntax

set attn

[value]

Example

set_attn 1

Response

Power control is set to 1 volt.

SET_EXT_INT_TYPE

Sets the type of interrupt (0–2). This command is for Module targets

only.

Syntax

set_ext_int_type

0 | 1 | 2

SET EXT_RSSI

Sets the sensitivity and range of RSSI reporting for both CDMA and

analog modes. This command is for Module targets only.

Syntax

set ext_rssi

{cmd_code, sub_sys, subcmd_code, cdma_rssi_sensitivity,

cdma_lower_threshold

, cdma_upper_threshold, analog_rssi_sensitivity,

analog_lower_threshold

, analog_upper_threshold}

cmd_code

is a 1-byte message ID.

sub_sys

is a 1-byte identifier for the generic subsystem, used for

AXESSTEL Proprietary

101