CANOGA PERKINS 9145 Network Interface Device User Manual

Page 13

Advertising
background image

Figure 7 – Bottom of 9145 showing Wall Mount Holes

c. Desktop/Shelf Placement: Place the 9145 on a secure, flat surface within reach

of the power and fiber optic cables. Leave clearance on the sides (1”), front (5”)
and rear (3”) for ventilation and to facilitate Interface Module Access, Cable
Access and Power Entry.

3. Insert Interface Modules:

a. Determine which Interface Modules are for the Extension (EXT) and User (USR)

Ports.

b. Insert a module into the appropriate slot and push firmly on the center of the front

panel. If it does not seat properly, pull the module out, inspect for bent connector
pins. If there are bent pins or other obstructions, contact Canoga Technical
Support for instructions. If all appears normal, reinsert.

c. When firmly seated, hand-tighten the screw on the Module’s front panel.

4. Connect Chassis Ground: The rear of the 9145 has a Grounding Lug for connecting the

9145 to Earth Ground. This is required for full electrical safety. Attach a 6 Gauge
copper cable between the Ground Lug and Earth Ground.

Wall Mounting Holes

Advertising