PREVENTION OF BLOOMING AND SMEAR

When the camera is aimed at a bright light, such as a spotlight, or a surface that reflects

bright light, smear or blooming may appear. Therefore, the camera should be operated

carefully in the vicinity of extremely bright objects to avoid smear or blooming.

SPECIFICATIONS

Pick-Up Device:

Scanning Area:

Scanning:

Horizontal:

Vertical:

Synchronization;

Video Output:

Horizontal Resolution;
Signal-to-Noise Ratio:
Dynamic Range:
Minimum Illumination:

Gain Control:

White Balance;
Aperture:

Electronic Light Control:

Super Dynamic II;

Electronic Shutter Speed:

Lens Mount:

ALC Lens:
Ambient Operating Temperature:
Ambient Operating Humidity:

Power Source:

Power Consumption:

Dimensions (without lens):

Weights (without lens):

768 (H)

X

494 (V) pixels. Interline Transfer CCD'’

4.8 (H) X 3.6 (V) mm (Equivalent to scanning area of

1/3" pick-up tube)
525 lines/60 fields/30 frames

15.734 kHz

59,94 Hz

Multiplexed Vertical Drive (VD2) by use of specified
camera drive unit.

'

1.0 V[p-p) NTSC composite 75 ii/through

camera drive unit

480 lines
50 dB (AGC OFF, weight ON)
46 dB

0.4 lx (0.04 footcandle) at F0.75 [Equivalent to 0.8 lx

(0.08 footcandle) at FI .4]

AGC ON or OFF (SET UP MENU) selectable
ATW or AWC (SET UP MENU) selectable
Set Variable (SET UP MENU) Sharp-Soft selectable by
detail level selector
ALC/ELC
ON or OFF (SET UP MENU) selectable
OFF, 1/1001/250, 1/500, 1/1 000 1/2 000, 1/4 000,

1/10 000 s selectable

CS-mount

DC drive

-10*C - -i-SO’C (14"F - 122*F)

Less than 90 %
From the specified monitor or camera drive unit
310 mA

6 8 ( W ) x 6 5 ( H ) x 1 2 6 ( D ) m m

[2-11/16" (W)

X

2-9/16" (H)

X

4-15/16' (D)]

0,375 kg (0,8 lbs.)

Weights and dimensions indicated are approximate,

Specifications are subject to change without notice.