A-net slot configuration, Setting the a-net slot range, A‑net slot configuration – Aviom 6416o User Manual

Page 35: Setting the a‑net slot range

Advertising
background image

26

F

roNt

P

ANel

F

eAtures

A-Net Slot Configuration

The A‑Net Slot section of the interface is used to set the range of A‑Net

Slots from which the 6416o will draw its audio channels. There are two

components: the A‑Net Slot display and the inc/dec buttons used to select

a value.

Press the up/down buttons to select an A-Net Slot range.

On a sixteen‑channel module like the 6416o, the A‑Net Slot display will move

in increments of sixteen Slots. The A‑Net Slot range display will wrap as it

reaches the end of the list of available values. The number shown in the

display corresponds to the first Slot in a group of sixteen sequential Slots,

one per channel button. The available base Slots are 1, 17, 33, and 49.

Starting Slot Displayed

A-Net Slot Range

01

Slots 1‑16

17

Slots 17‑32

33

Slots 33‑48

49

Slots 49‑64

Keep in mind that the number of available Slots is determined by the current

network sample rate as set by the Clock Master.

Setting the A-Net Slot Range

To set a Slot range, use the inc/dec selection buttons found below the A‑Net

Slot display to select the desired range. When the selection button is pressed,

the new range displayed will start to blink, as will the Enter/Cancel button’s

LED. This indicates that confirmation is required to complete the change.

Press

E

ntEr

to set a new range or press

C

anCEl

to exit without changing the

A‑Net Slot range and return to the previous setting. If no press of the Enter/

Cancel button is detected within a brief period of time, the interface will

automatically cancel the range change request, returning to the previous

state.