Sample Rate

Pro64 networks can operate at sample rates in three ranges without the use

of sample rate converters. The current network sample rate also determines

the number of available A‑Net Slots.

Sample Rate

A-Net Slots Available

1x 44.1/48kHz

64

2x 88.2/96kHz

32

4x 176.4/192kHz

16

In an all‑analog network, the sample rate can be set at the Control Master to

the following:

44.1kHz

48

• kHz

88.2

kHz

96

• kHz

176.4

kHz

192

kHz

When an external clock is used with a Pro64 digital I/O device, the system can

lock to any sample rate within a range that is ±10% of the currently displayed

sample rate.

Pro64 Series Supported Sample Rates

Sample Rate

Minimum

Maximum

1x 44.1/48kHz

39.7kHz

52kHz

2x 88.2/96kHz

79.4kHz

104kHz

4x 176.4/192kHz

158.8kHz

208kHz

Changing the Sample Rate

The network sample rate can be changed only at the Control Master.

Changing the sample rate is done with the selection button found below the

Sample Rate LED readout.

To choose a new sample rate, press the selection button beneath the sample

rate list. Pressing the button selects the next sample rate in the list and

immediately starts blinking the new rate’s LED and the Enter/Cancel LED;

confirmation is required. To confirm the new sample rate, press the

E

ntEr

button. To exit without changing the sample rate, press