Gpio plugs, Midi/gpio cable lengths, Factory default settings – Aviom 6416o User Manual

Page 88: Gpio plugs midi/gpio cable lengths

Advertising
background image

79

s

PeciFicAtioNs

GPIO Plugs

Plugs used with the GPIO terminal blocks have the following specifications.

Pitch

3.81 mm

Number of positions

8

Type of connection

Screw

Screw thread

M 2

Conductor cross section AWG/

kcmil

minimum 28

maximum 16

Plugs used with Pro64 products are compatible with Phoenix

Contact™, part number 1803633, or equivalent.

MIDI/GPIO Cable Lengths

To meet the EN55103‑2 (Electromagnetic Susceptibility/Immunity)

Specification, any cables connected to the MIDI and/or GPIO ports must not

exceed three meters in length. Use of cables longer than three meters will

not guarantee equipment conformance to EN55103‑2.

Factory Default Settings

When a Pro64 module is reset to the factory default settings using Function

16, the following settings are restored:

A‑Net Slot is set to 1.

Auto Mode is selected.


• Sample Rate is set to 48kHz.

All audio channels are muted and deactivated for

Auto,

Manual, and Managed Modes.
All stereo links are deactivated for Auto, Manual, and

Managed Modes.
Managed Mode is deactivated.


• Edit Lock is set to off.
• Password protect is off.

The system

password value for the module being reset is

“1‑1‑1‑1.”
All Virtual Data Cables are deactivated.

Advertising