b

uildiNg

A

P

ro

64 N

etwork

Digital Copies in Manual Mode

Creating a digital split in Manual Mode follows most of the rules defined for

Auto Mode splits. Any output modules connected in series to an existing

output module can output the same audio as long as the A‑Net Slot range

and A‑Net Receive Port settings are configured properly, and as long as no

input modules installed overwrite the audio. However, the location of the

Pro64 output modules used for the splits will impact the front‑panel transmit

port settings of the input modules.

In the previous example of a stage and front‑of‑house system, adding a

digital copy of the FOH engineer’s inputs for a recording system can be

accomplished by connecting Pro64 output modules to the input module at

front‑of‑house. Unlike Auto Mode, however, this input module needs to be

set to send audio data to its A‑Net Port B in order to make the digital split

work.