Use stored sample alignment lock value, Use default sample alignment lock value – Aviom 6416o User Manual

Page 51

Advertising
background image

42

o

PerAtiNg

s

Ystem

u

PdAte

is changed, or when the system configuration changes. (Changes include the

addition/subtraction of Pro64 modules, different wiring schemes, etc.)

Use Stored Sample Alignment Lock Value

When a new sample alignment lock value has been generated and stored,

Function 13 can be used to activate and lock in this value for use throughout

the network. This Function can only be performed at the Control Master

when the network is unlocked.

To use the stored value, press the

F

unCtion

button, followed by the

C

hannEl

13

aCtivE

button. The Enter/Cancel LED and the sixteen yellow channel meter

LEDs will flash. Press

E

ntEr

to use the stored value, or press

C

anCEl

to exit

without changing the sample alignment value (the system reverts to using

the default value).

The stored sample alignment value remains in force even when the network

is power cycled. When the network is reconfigured or when the sample rate

is changed, a new value should be calculated.

Use Default Sample Alignment Lock Value

The system calculates a sample alignment lock value to be used as the

default every time the network is powered up, or when the sample rate is

changed. Function 14 can be used at the Control Master to set the network

to use the default value. (Function 13 is used to instruct the system to use a

stored value. )

To set the network to use the default sample alignment value, press

F

unCtion

,

followed by the

C

hannEl

14

aCtivE

button. The sixteen yellow channel meter

LEDs and the Enter/Cancel LED will flash. Press

E

ntEr

to use the default value,

or press

C

anCEl

to exit without changing the current value.

Use Function 11 (Get Sample Alignment Info) to display the current value in

use—default or stored.