Firmware Update

The Pro64 operating system firmware can be updated in the field using a

PC and the Pro64 Update Tool. Modules can be updated over A‑Net, while

part of an active audio network, or in local mode where no other modules

are connected at the time the update is being performed (such as may

be required for a bench configuration when setting up modules prior to

installation).

Updating a module requires the Aviom Pro64 Update Tool application, a PC

host computer with RS‑232 connection capability, a null modem DB9 cable,

and the update file for the particular Pro64 device being updated. Refer

to the Aviom website for information about the availability of the latest

firmware upgrades and feature updates.

Firmware Update Connections

To update modules via A‑Net, a host computer is connected to the network’s

Control Master via the RS‑232 port in the Virtual Data Cable section of the

rear panel. Individual modules are then selected and updated from within

the Pro64 Update Tool. Updates can be applied to the Control Master or a

slave device.

To update via A‑Net, make sure that no RS‑232 or MIDI VDC resources are

configured on the Control Master. (Refer to the Virtual Data Cable information

elsewhere in this document.) Then, enter Managed Mode by pressing the

M

anagEd

button on the Control Master.

To update modules locally, the computer is connected directly to the module

being updated, via the RS‑232 port as described above. The Pro64 Update

Tool application must also be set to its local update mode. (See the Pro64

Update Tool Help file for more information.)

Baud rates for data transfer must be set the same on the Pro64 device and PC

host running the Pro64 Update Tool. Refer to the VDC RS‑232 baud rate (page

59) to learn how to set the baud rate parameters. On the Pro64 module, RS‑

232 must be configured for eight data bits, no parity, and one stop bit. Also,

refer to the firmware update instructions that come with the Pro64 update

application for additional information on setting up the PC host.

Firmware Update - Local

Function 15 enables a Pro64 module to receive new firmware from a host PC

connected to the RS‑232 port on the module’s rear panel. Updates can be

applied to a Pro64 module set to be a Control Master or slave device.