Control master errors, A-net slot configuration, A‑net slot configuration – Aviom 6416dio User Manual

Page 47

Advertising
background image

37

F

roNt

P

ANel

F

eAtures

enumerated and the blue A‑Net LEDs on all Pro64 devices will be lit. On the

Control Master device, its red Control Master LED will also be lit. The Control

Master LED will be off on all remote/slave modules in a network.

Refer to the Control Master section of this User Guide (page 20) for additional

information about the Control Master features and functions.

Control Master Errors

The following rules apply to the Control Master and active Pro64 networks.

If a slave module in an active network is incorrectly switched to be a Control

Master (in addition to the network’s already functioning Control Master),

that module’s Control Master LED will light and the A‑Net LED will go out to

indicate the error. The Control Master LED will remain lit until the module is

returned to slave status.

If a newly powered module set to be the Control Master is added to an active

running network (one that already has a valid Control Master), the new

module’s Control Master LED will light. Its audio I/O resources will remain

unavailable until the module is returned to slave status. All audio on this

module will be muted until the module is set to be a slave.

If the Control Master is removed from a functioning network (by being

disconnected, power failure, etc.), all slave units will reset and audio will be

muted. Slave units will wait for a new Control Master to be designated and at

that point will begin the enumeration process.

A-Net Slot Configuration

The 6416dio Digital I/O Module has two sets of A‑Net Slot interfaces, one

for input channels and another for output channels. These can be set

independently as required.

The A‑Net Slot setting in the Input section of the user interface is used to

set the range of A‑Net Slots that the 6416dio will use to send its active audio

channels into the network. The Slot setting in the Output section of the

interface sets the range of A‑Net Slots that the 6416dio will output as AES3

digital audio data to compatible digital devices.

There are two components to the A‑Net Slot selection interface: the A‑Net

Slot display and the inc/dec buttons used to select a value.

Advertising