Vdc configuration – Aviom 6416dio User Manual

Page 61

Advertising
background image

51

vdc c

oNFigurAtioN

With an edit locked 6416dio module’s input channels set to the A-Net Slot

Range starting at 17, pressing the Channel 2 button displays A-Net Slot

18. Pressing the Channel 3 button will display “19,” pressing the Channel 4

button will display “20,” etc.

Channel activation status is not affected by the use of the query function. It

is used for information only.

To exit the query function, press

E

dit

l

oCk

followed by

E

ntEr

to return to

normal operation.

Pro64 modules are set to provide query information whenever the network

is in Managed Mode.

VDC Configuration

Pro64’s Virtual Data Cables provide an easy way to distribute control signals

throughout a network, greatly expanding the possibilities for using and

distributing MIDI, GPIO, and RS‑232/422 control signals. A‑Net provides the

ability to send these control data over greater distances than previously

possible with traditional analog connections. And with MIDI and GPIO

connections, infinite numbers of copies of the control data are available

everywhere in the network.

P

N

ote

: Not all Pro64 modules have the same complement of VDC I/O. The

6416dio Digital I/O Module has the ability to use the GPIO, RS‑232,

or RS‑422 Virtual Data Cable types. MIDI is not supported. MIDI data

will, however, pass through the 6416dio to other Pro64 network

modules that can make use of this data type.

Fourteen VDC Slots are available at all times; VDCs are not affected by the

current sample rate or network mode. The makeup of the VDC Slots is user