Vdc configuration – Aviom 6416dio User Manual
Page 61
51
vdc c
oNFigurAtioN
With an edit locked 6416dio module’s input channels set to the A-Net Slot
Range starting at 17, pressing the Channel 2 button displays A-Net Slot
18. Pressing the Channel 3 button will display “19,” pressing the Channel 4
button will display “20,” etc.
Channel activation status is not affected by the use of the query function. It
is used for information only.
To exit the query function, press
E
dit
l
oCk
followed by
E
ntEr
to return to
normal operation.
Pro64 modules are set to provide query information whenever the network
is in Managed Mode.
VDC Configuration
Pro64’s Virtual Data Cables provide an easy way to distribute control signals
throughout a network, greatly expanding the possibilities for using and
distributing MIDI, GPIO, and RS‑232/422 control signals. A‑Net provides the
ability to send these control data over greater distances than previously
possible with traditional analog connections. And with MIDI and GPIO
connections, infinite numbers of copies of the control data are available
everywhere in the network.
P
N
ote
: Not all Pro64 modules have the same complement of VDC I/O. The
6416dio Digital I/O Module has the ability to use the GPIO, RS‑232,
or RS‑422 Virtual Data Cable types. MIDI is not supported. MIDI data
will, however, pass through the 6416dio to other Pro64 network
modules that can make use of this data type.
Fourteen VDC Slots are available at all times; VDCs are not affected by the
current sample rate or network mode. The makeup of the VDC Slots is user