• Password protect is off.

The system

password value for the module being reset is

“1‑1‑1‑1.”
All Virtual Data Cables are deactivated.

The Control Master setting is hardware controlled and dependent upon the

rear‑panel DIP switch settings. These settings are not changed when factory

defaults are restored.

VDC configuration for GPIO type—Isolated or TTL—is not reset. VDC baud

rate, parity, and stop bit settings for RS‑232/422 communication are not

reset. These are hardware settings configured via the DIP switches in the

VDC section of the rear‑panel part of the interface.

Restoring factory defaults is a local function; only the module where the

function is engaged will be reset.