v

irtuAl

d

AtA

c

Ables

Virtual Data Cables

Two types of Virtual Data Cable (VDC) ports are available on the rear panel

of the 6416dio Digital I/O Module. Fourteen VDC Slots are available system‑

wide, regardless of the current network mode (Auto or Manual). Virtual Data

Cables are not affected by the network sample rate, channel activation

settings, or gain settings.

When a Pro64 module requests to activate a Virtual Data Cable, the Control

Master checks the entire network to ensure that the requested VDC is

available. Depending on the type of VDC requested, one or more VDC Slots

must be available before the request can be granted.

When a VDC Slot has a valid input assignment, the Control Master broadcasts

this information to the entire network. Each module in the network will

display the In Use LED for any valid Virtual Data Cable input.

VDC Slot 11 on the 6416dio

is set to receive GPIO In

from the rear-panel jack.

A remote Pro64 device

is set to output the GPIO

data.

See the VDC info elsewhere in this User Guide for help configuring and using

the fourteen available Virtual Data Cables.

GPIO

GPIO (General Purpose Input/Output) can be used to send contact closure

or voltage‑type control signals through the network. Four input and four

output blocks are provided. Each terminal block can be individually wired.

GPIO inputs can be individually configured to be either Isolated or TTL.