- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

Point

To input the ID number for the DL-PN1 into ID, refer to the instruction
manual for each PLC. When inputting the ID number of the sensor
amplifier connected to the DL-PN1 into ID, input the smaller of the Slot
I Address and Q Address. If Q Address will be input, add
32768(0x8000).

Access Address (Slot 0)

RECORD

A value is input when reading. Inputs a value when writing.

VALID

Replies as to whether the action was valid.

BUSY

Replies as to whether the unit is busy.

ERROR

Replies as to whether there is an error.

STATUS

Replies with status information (including error information).

LEN

Replies the length of the reply data.

Parameter name

Description

Index

(DEC)

Function name

Description

Data

type

Attribute

Value

0

Key lock

The sensor amplifier enters
the key lock state.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

1

Key unlock

The key lock of the sensor
amplifier is canceled.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

2

Power saving function
(ECO)

The sensor amplifier enters
the eco mode.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

3

Power saving function
(ECO) cancel

The eco mode of the sensor
amplifier is canceled.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

4

Light emission stop
request

Light emission of the sensor
amplifier is stopped.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

5

Light emission stop cancel

Light emission stop of the
sensor amplifier is canceled.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

6 to 14

Reserved for system

15

Initialization request

Initializes the sensor
amplifier.

2byte

WORD

W

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

16 to 31 Reserved for system

32

DL-PN1 error state

Stores the DL-PN1 error
status.

"Types of error and error

code" (page 29)

2byte

WORD

R

33

Number of connectable
units

Stores the number of sensor
amplifiers connected to the
DL-PN1.

2byte

INT

R

0 to 15

34 to 63 Reserved for system