KEYENCE DL-PN1 User Manual

Page 22

Advertising
background image

20

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

*1 The error content of the sensor amplifier can be checked by noting the ON/OFF

state of each bit.

OFF (0): No error; ON (1): Error

More than one error may occur simultaneously. For details of each error, refer to the

IB Series User's Manual.

*2 Details of output status can be checked by noting the ON/OFF state of each bit.

167

Error output mode

DINT

R/W

0

0: Normal mode (Default)
1: LX2 compatible mode

168

Hysteresis for trigger level

DINT

R/W

0

0: Default
1: User setting

169

Hysteresis set value for
trigger level

*16

DINT

R/W

1.00

0.00 to 999.99

170 to

191

Reserved for system

192

Group6 Entry count

DINT

R

11

193

Product code

DINT

R

Main unit:=4020
Expansion unit:=4021

194

Reserved for system

195

Transmitter head model

DINT

R

0: Sensor head is not connected,

or light receiver is connected.

1: Light transmitter of IB-01 is

connected.

2: Light transmitter of IB-05 is

connected.

3: Light transmitter of IB-10 is

connected.

4: Light transmitter of IB-30 is

connected.

196

Receiver head model

DINT

R

0: Sensor head is not connected,

or light transmitter is connected.

1: Light receiver of IB-01 is

connected.

2: Light receiver of IB-05 is

connected.

3: Light receiver of IB-10 is

connected.

4: Light receiver of IB-30 is

connected.

197 to

199

Reserved for system

200

Product name 1

*20

DINT/

STRING

R

Main unit:="IB-1"
Expansion unit:="IB-1"

201

Product name 2

*20

DINT/

STRING

R

Main unit:="000/"
Expansion unit:="050/"

202

Product name 3

*20

DINT/

STRING

R

Main unit:="1500"
Expansion unit:="1550"

203

Product name 4

*20

DINT/

STRING

R

Main unit:=""
Expansion unit:=""

204 to

217

Reserved for system

218

Unit

219 to

223

Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

Advertising