Appendix, Specifications, The specifications of the dl-pn1 are as follows – KEYENCE DL-PN1 User Manual

Page 26

Advertising
background image

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

24

Appendix

Specifications

The specifications of the DL-PN1 are as follows:

Product name

PROFINET I/O Communication Unit

Model

DL-PN1

Suitable network

PROFINET I/O communication

Ethernet

Compliant standards

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps (100BASE-TX)

Transmission medium

STP cable or Category 5e or higher UTP cable (100BASE-TX)

Maximum cable length

100 m

PROFINET

Compatible functions

Data I/O communication
Record data communication

No. of connectable

PROFINET I/O controllers

1

Update Time

2 - 512 ms

GSDML version

V2.3

Conformance class

Conforms with Conformance Class A

Conformance test version

Conforms with V2.2.4

Suitable protocols

LLDP, DCP

Sensor connection

specifications

Connectable sensors

Sensor amplifiers with D-bus support

Number of connectable

sensor units

4 units max.

Indicator lamps

Link/activity indicator (LINK/ACT): Green LED
System failure indicator (SF): 2-color (orange/red) LED
Bus failure indicator (BF): Red LED
Sensor communication indicator (D-bus): 2-color (green/red) LED

Power voltage

20 to 30 V DC, including ripple (p-p)10%
supplied from the connected sensor amplifiers

Power consumption

1500 mW or less (at 30 V 50 mA max.)

Environmental

resistance

Operating ambient air

temperature

-20 to +55°C (no freezing)

Operating ambient air

humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm, 2 hours each in X, Y, Z
directions

Pollution degree

2

Materials

Main unit: Polycarbonate

Weight

Approx. 70 g

Advertising