KEYENCE DL-PN1 User Manual

Page 20

Advertising
background image

18

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

130

Measurement mode

DINT

R/W

0

0: Percent mode
1: Dimension mode

131

Received/Blocked light mode

DINT

R/W

0

0: Received light mode
1: Blocked light mode

132

Reserved for system

133

Averaging/High-pass filter

DINT

R/W

5

Averaging
0:

1 time

1:

2 times

2:

4 times

3:

8 times

4:

16 times

5:

64 times

6:

256 times

7:

1024 times

8:

4096 times

9:

16384 times

High-pass filter
10: 0.1Hz
11: 0.2Hz
12: 0.5Hz
13: 1Hz
14: 2Hz
15: 5Hz
16: 10Hz
17: 20Hz
18: 50Hz
19: 100Hz

134

Output mode

DINT

R/W

0

0: N.O (Normal open)
1: N.C (Normal close)

135

Reserved for system

136

Hold function setting

DINT

R/W

0

0: Sample hold
1: Peak hold
2: Bottom hold
3: Peak-to-peak hold
4: Auto peak hold
5: Auto bottom hold

137

Auto hold trigger level

*7

DINT

R/W

+90.00

-999.99 to +999.99

138

Timing input setting

DINT

R/W

0

0: Level
1: Edge

139

Delay Timer

DINT

R/W

0

0: OFF
1: On delay
2: Off delay
3: One-shot

140

Timer duration

DINT

R/W

60

1 to 9999

141

Hysteresis

DINT

R/W

0.00

0.00 to 999.99

142

Analog output scaling

*17
*19

DINT

R/W

0

0: Initial state
1: Free range

143

Analog output upper limit

*7

*17
*19

DINT

R/W

+100.00

-999.99 to +999.99

144

Analog output lower limit

*7

*17
*19

DINT

R/W

0

-999.99 to +999.99

145

External input setting

*18

DINT

R/W

0

0: Default
1: User setting

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value