KEYENCE DL-PN1 User Manual

Page 18

Advertising
background image

16

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

39

Peak-hold value in hold mode

*4
*5
*7

DINT

R

-999.99 to +999.99

40

Bottom-hold value in hold
mode

*4
*6
*7

DINT

R

-999.99 to +999.99

41

Reserved for system

42

Analog output value

*8

DINT

R

Analog voltage output:
-5.000 to +5.000
Analog current output:
+04.00 to +20.00

43

Bank status

DINT

R

0: Bank 0
1: Bank 1
2: Bank 2
3: Bank 3

44

Timing status

DINT

R

0: During Sampling
1: Not during sampling

45 to 49 Reserved for system

50

Laser emission stop status

DINT

R

0: Laser emitting
1: Laser stopped

51

Abnormal setting

*9

DINT

R

0: Normal setting
1: Abnormal setting

52

External input status

*21

DINT

R

0 to 15

53

EEPROM writing result

*10

DINT

R

1

0: Writing
1: Normal termination
2: Abnormal termination

54

Zero shift executing result

*11

DINT

R

1

0: Executing
1: Normal termination
2: Execution impossible

55

Reset execution result

*11

DINT

R

1

0: Executing
1: Normal termination
2: Execution impossible

56

System parameter current
state

*12

DINT

R

0

Main unit: 0 to 9
Expansion unit: 0 to 1

57

Reserved for system

58

Reference light registration
result

DINT

R

1

0: Executing
1: Normal termination
2: Reference light registration error

1 (Light insufficient error)

3: Reference light registration

error 2 (Interfering light error)

59

Adjust result

DINT

R

1

0: Executing
1: Normal termination
2: Adjust error 1 (Light

insufficient error)

3: Adjust error 2 (Interfering

light error)

4: Adjust error 3 (Excess light error)

60

Tuning result

*13

DINT

R

1

0: Executing
1: Normal termination
2: Execution impossible

61

Correction result

*22

DINT

R

1

0: Executing
1: Normal termination
2: Execution impossible

62 to 63 Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value