Data processing time – KEYENCE DL-PN1 User Manual

Page 28

Advertising
background image

26

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

Data Processing Time

The data update time for data I/O communication is shown below.

Maximum data processing time = (1) + (2) + (3) + (4)

(1) I/O controller data update time
(2) Network data update time
(3) Data update time between the DL-PN1 and sensor amplifiers

(4) Sensor amplifier response time

For (1) and (2), see manuals for each model.
For (4), refer to the User's Manual of each sensor amplifier connected to the DL-PN1.

Number of connected sensor

amplifiers

Output, judgment value, or current

value

1

7.8 ms

2

9.8 ms

3

13.8 ms

4

15.8 ms

(4)

(3)

(2)

(1)

DL-PN1

LINK

/ACT

RST

SF

BF

DL

Sensor amplifier

master

Advertising