A warning – Kenmore Washer/Dryer User Manual

Page 17

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

I. THREE-WIRE ELECTRICAL

CONNECTION TO RECEPTACLE

Use a 3-wire power supply cord:

A WARNING

M

l

Fire Hazard

Use a new UL approved 30 ampere
power supply cord.

Use a UL approved strain relief.

Disconnect power before making

electrical connections.

Connect neutral wire (white or center

wire) to center terminai (silver).

Ground wire (green or bare wire)
must be connected to green ground
connector.

Connect remaining 2 supply wires
to remaining 2 terminals (gold).

Securely tighten all electrical
connections.

Failure to follow these instructions
can resuit in death, fire, or electrical
shock.

Local codes may permit the use of
a U.L.-listed, 120/240-volt minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the laundry center must end with

ring terminals or spade terminals with
upturned ends.

Do not use an extension cord with

this laundry center.

Do not connect plug end of power
supply cord into a live receptacle
before connecting power supply cord
to laundry center terminal block.

The power supply cord must have three,

No.-10 copper wires to match a three-
wire receptacle of NEMAType 10-30R.

Spade terminals

with upturned ends
(OR ring terminals)

This blade connected

Three-wire receptacle
(NEMAType10-30R)

1

y

17

Advertising