This laundry center may be converted
to exhaust out the right or left side. To
convert the laundry center, the following

kits MUST be used.

.

Side Exhaust Kit No. 3391335 (white)

Side Exhaust Kit No. 3391336 (almond)

Follow the instructions in the kit to

avoid operational and personal hazards.
These kits are available at your local
Sears store or Sears Service Center.

DETERMINE VENT LENGTH
Maximum Exhaust Lengths:

Rear Exhcwst. The maximum length

of the rear exhaust system depends
on the type of vent, the number of
elbows and the type of exhaust hood.

Refer to the chart belovir.

Side Exhaust. Side exhaust adds

a 90° turn inside the laundry center.

To determine maximum exhaust

length, add one 90° turn to the chart.

Typical installations for left or right side
exhausting

NOTE:

Avoid pushing the laundry center

tightly against a wall. This can crush or
kink the vent. Use the straightest path you
can, where possible, to avoid 90° turns.

EXHAUST HOODrrPE

Number of

90° Turns

Maximum length of 4-inch

diameter rigid heavy metal vent.

0

42 ft.

40 ft.

35 ft.

1

34 ft.

32 ft.

27 ft.

2

26 ft.

24 ft.

19 ft.

Number of

Maximum length of 4-inch

90° Turns diameter flexible heavy metal vent.

0

26 ft.

25 ft.

20 ft.

1

21 ft.

21 ft.

16 ft.

2

16 ft.

15ft.

10 ft.