II. THREE-WIRE ELECTRICAL

CONNECTION (DIRECT WIRE)

Prepare cable as directed:

A WARNING

M

Fire Hazard

Use 10 gauge solid copper wire.
Use UL approved strain relief.

Disconnect power before making

electrical connections.

Connect neutral wire (white or center

wire) to center terminal (silver).

Ground wire (green or bare wire)
must be connected to green ground
connector.

Connect remaining 2 supply wires

to remaining 2 terminals (gold).

Securely tighten all electrical
connections.

Failure to follow these instructions
can result in death, fire, or electrical
shock.

The laundry center can be connected

directly to fused disconnect or circuit
breaker box with three-wire, flexible
armored or nonmetallic sheathed
copper cable (with grounding wire). All

current-carrying wires must be insulated.

A conduit connector must be installed at
junction box. Allow four feet of slack in the

line so laundry center can be moved if
servicing is ever necessary.

GROUNDING INSTRUCTIONS

This appliance must be connected to
a grounded metal, permanent wiring i
system; or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding terminal or
lead on the appliance.

STEP 1

. Disconnect power.

STEP la.

Strip 3V2 inches of outer

covering from end of cable. If using
3-wire cable with grounding wire, cut
the bare wire even with outer covering.

STEP 1b.

Cut 1 inch of insulation from

the end of each insulated wire. Shape
the end of each wire into a “U" shaped

hook.