The problems described in this table are failures caused, in general, by improper operation or connection of the

transceiver, not by defective components. Examine and check according to the following table.

6-3. IN CASE OF DIFFICULTY

Symptom

Probable cause

Corrective action

Indicators do not light and no

receiver noise is heard when the
POWER switch is turned on.

All the indicators flash.

1. Low voltage.

2. With optional DC cable:

1) Bad power cable or

connections.

2) Blown power supply fuse.

1. Recharge/replace the battery.

2.

1) Check cables and connections.

2) Check for the cause of the

blown fuse and replace the
fuse.

No sound from the speaker.
No signal can be received.

1. Squelch is closed.

2. With the TSU-7: CTCSS is operat­

ing.

3. DTSS is operating.

4. Paging is operating.

1. Turn the SQL control counter­

clockwise.

2. Press the F key, then the 2/CTCSS

key to turn off the CTCSS.

3. Press the DTSS key to turn off the

DTSS.

4. Press the F k e y , t h e n t h e

DTSS/PAG key to turn off the Pag­

ing.

No control works.

1. LOCK is ON.

2. T.ALT is ON.

1. P r e s s t h e F k e y , t h e n t h e

ENT/LOCK key to t u r n o f f the
LOCK.

2. Press the F key, then the 3/T.ALT

key.

M e m o r y c h a n n e l c a n n o t b e
recalled.

Nothing is stored in the m e m o r y

channel.

See section 4-4-5 : Memory Entry

Memory cannot be backed up.

1. Battery voltage is low.

2. Battery case removed.

1. Recharge the battery.

2. Install the Battery case.