Figure 2-15 – Cabletron Systems SPECTRUM TRMMIM User Manual

Page 46

Advertising
background image

Using the TRMMIM Hub View

2-30

Managing the Hub at the Module Level

Figure 2-15. The Module FNB Configuration Window

The Module FNB Configuration window contains the following fields:

Board:

This field displays the board number of the module for which the Module FNB
Configuration window is being displayed.

FNB

This field lists the FNB number for each FNB interface available for the selected
module. For the TRMMIM, only FNB 1 is available.

Left Connect

This field lists the FNB left connection status for each corresponding FNB in the
list. Possible values for this field are Attached or Wrap.

Right Connect

This field lists the FNB right connection status for each corresponding FNB in the
list. Possible values for this field are Attached or Wrap.

Bypass

This field lists the FNB Bypass state for each corresponding FNB in the list.
Possible values for this field are Enabled or Disabled.

RP Bypass

This field lists the Ring Port Bypass state for each corresponding FNB in the list.
Possible values for this field are Enabled, Disabled, or NA (not applicable). The
default setting for this field is Disabled. Modules without ring ports will display
NA.