Beacon configuration, Beacon configuration -23 – Cabletron Systems SPECTRUM TRMMIM User Manual

Page 73

Advertising
background image

Viewing Ring-level Information

3-23

Ring Map

Beacon Configuration

The Beacon Configuration window allows you to enable and configure the
parameters for the Automatic Beacon Recovery Process (ABRP). If the Beacon
Recovery option is enabled, the TRMMIM will automatically attempt to repair its
ring when it detects an unusually high concentration of hard errors that have not
been corrected by normal ring recovery procedures. ABRP is a sequential process
that is designed to isolate the source of the errors as quickly as possible.

If a frequent occurrence of hard errors is detected, the TRMMIM first determines
if the problem is internal or external to the chassis by turning each ring port off to
see if the error condition clears. If the beaconing goes away (because it is external
to the hub), the TRMMIM enables the Ring In/Ring Out ports at the interval
specified in the Ring Port Retry Delay field for the number of times specified in
the Ring Port Enable Retry field to see if the beacon condition on the network has
cleared. If the beaconing continues after the specified number of retries, the faulty
Ring In/Ring Out ports remain disabled.

If the beaconing continues when the Ring In/Ring Out ports are shut off, then the
problem is internal to the hub. The TRMMIM individually bypasses each module
to isolate the one with the fault (as evidenced by ring recovery on bypass). When
the module with the fault is identified, the module is reinserted, and that
module’s ports are turned off one by one until the ring recovers again. The last
port turned off is considered to be the failing port. Once the failing port is
identified, all ports which were previously turned off are turned back on. For
devices running older versions of firmware, the failing port will be retried once at
a pre-determined interval, and if beaconing continues, remain disabled; for newer
firmware versions, the port will be retried at the interval specified in the Station
Port Retry Delay

field for the number of times specified in the Station Port

Enable Retry

field. Again, if beaconing continues, the port will remain disabled.

Ports disabled by ABRP must be manually re-enabled before they can be used
again; this prevents a user from rebooting a problem station which may bring the
ring down.

Once ABRP is completed, the TRMMIM generates traps to the remote
management workstation which will pinpoint the problem’s cause, including:

the beaconing adapter’s address

its NAUN address

the type of beacon

the port(s) and/or module(s) bypassed, and

the duration of the beaconing condition

To launch the Beacon Configuration window and configure beacon recovery
parameters:

1.

Click on

at the top of the Ring Map window.

2.

Drag down to Beacon Configuration, and release. The Beacon
Configuration window,

Figure 3-11

, will appear.

Advertising