Installation (continued) – Campbell Hausfeld CE7000 User Manual

Page 11

Advertising
background image

Series CE7000, CE8000 and CE9000

www.CH-Commercial.com

11

Installation (Continued)

luBriCAtion

ThIS UNIT CONTAINS NO OIL. Before operating

compressor, fill to the center of the sight gauge

(see Figure 14).

Using any other type of oil may shorten pump

life and damage valves.

recommended oil (2 options)
• Single viscosity SAE 30 ISO100 non-detergent compressor

oil� Available from Campbell Hausfeld, part number
ST126700AV.

• 10W30 synthetic oil such as Mobil 1

®

oil Capacity
CE7000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2 quarts
CE8000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 quarts
CE9000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4-1/2 quarts

Fill the pump with oil to the center of the sight gauge using oil
fill opening (see Figure 14)� Do NOT fill the pump through the
breather cap opening as this may cause oil to leak and spray
out during operation.
The Automotive Series compressor models include a low oil
guard� This device monitors the oil level in the crankcase
and will shut off the compressor if the oil level gets too low�
See separate low oil guard manual for complete operating
instructions�

NOTE: Some residual oil may still be in the pump from factory
testing leaving a thin coat on the sight gauge; however, there is
not enough oil to operate the unit�

figure 14

Breather Cap

Oil Drain Plug

Oil Drain Plug

Oil Fill Plug

Oil Fill Plug

SiGHt GAuGe

Full

Low

Advertising
This manual is related to the following products: