Troubleshooting Guide for New Installations (Continued)

SyMptoM

CAuSe

Solution

Unit runs very noisy

Damage to the compressor

Check to make sure the compressor has not been damaged in the
shipping or installation� Make sure the belt guard was not damaged�
Belt guard should not be making contact with flywheel or pulley.

Loose fasteners

Check all bolts and nuts to assure they did not loosen during shipping�

Loose flywheel or pulley

Check to assure pulley and flywheel are correctly tightened�

Improper installation

If unit is left on skid it may cause excessive vibration� Remove unit from
skid and mount loosely to floor with vibration pads and anchor bolts�
Do not tighten bolts tight. Leave nut loose approximately 1/8 inch from
compressor foot�

Oil in discharge air or
out crankcase breather

Break in period

Some oil in the exhaust air is normal during the break-in period and
during heavy usage after the break-in period� Oil discharge should
reduce as hours are accumulated on the unit�

Wrong type of oil

Do not use SAE-30 automotive type oil. Using the wrong oil can cause
problems with the pump and will void the warranty� Only use the oils
that the operating manual recommends (see Lubrication section)�

Improper environment

Unit should not be installed in a poorly vented area or exposed to
extreme cold or hot conditions� Normal operating range should be
between 32°F and 100°F�

Compressor seems to
run hot

Rotation incorrect

Check to make sure the compressor is running the direction of the
flywheel arrow� Air flow should be so that the flywheel directs air across
the head of the pump� Standing in front of the compressor (non-belt
guard side) air should flow back to front�