Haltech E6K User Manual

Page 35

Advertising
background image


29

RPM Limit Type

The RPM Limit can either be a fuel cut or an ignition cut. This field determines what
form of limit will be used. Be careful using an ignition cut on an engine with a
catalytic converter, as the unburnt fuel can damage it.


Units

The Haltech E6K programming software can display parameters in either Metric or
US units.


RPM Mode

The E6K fuel and ignition maps may be arranged either in 500 rpm increments to
10,500 rpm, or in 1000 rpm increments to 16,000 rpm. Select the high - or low - rpm
mode here. Changing settings alters the way the ECU reads the Maps, and will change
the tuning of the engine dramatically. Do not change this setting once tuned unless
necessary.


Road Speed Value

This value calibrates the Road Speed reading. Some applications in Advanced Mode
cannot use the Road Speed input trigger, and this field will not be displayed.


System Mode

This field sets the operating mode for the software. The software can be used in either
Basic or Advanced Mode. Most installations will only require the Basic Mode. To
determine if you need to use the Advance Mode, see the Introduction.

Advertising