Parameter Function

Event
Type

Event type: There are four types. Local input/network input/IPC

external/IPC offline alarm.

Local input alarm: The alarm signal system detects from the

alarm input port.

Network input alarm: It is the alarm signal from the network.

IPC external alarm: It is the on-off alarm signal from the

front-end device and can activate the local NVR.

IPC offline alarm: Once you select this item, system can

generate an alarm when the front-end IPC disconnects with

the local NVR.

Alarm in

Select corresponding alarm channel.

Enable

You need to draw a circle here so that system can detect the alarm
signal.

Type

There are two options: normal open and normal close. NO becomes

activated in low voltage, NC becomes activated in high voltage.

Period

Alarm record function becomes activated in the specified periods.

There are six periods in one day. Please draw a circle to enable
corresponding period.

Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.

Click OK button, system goes back to alarm setup interface, please
click save button to exit.

Anti-dither System only memorizes one event during the anti-dither period. The

value ranges from 0 to 15s.

Relay Out Enable alarm activation function. You need to select alarm output port

so that system can activate corresponding alarm device when an
alarm occurs.

Alarm
Latch

System can delay the alarm output for specified time after alarm ended.

The value ranges from 10 seconds to 300 seconds.

Record
Channel

System auto activates current channel to record once an alarm occurs

(working with alarm activation function). Please note current device

shall be in auto record mode

Record
Latch

System can delay the record for specified time after an alarm ended.

The value ranges from 10s to 300s.

Email

Please draw a circle to enable email function. System can send out

email to alert you when an alarm occurs and ends.

Screen
display

After enabled, alarm info will be prompted out on the local output end.

That is to say, the alarm prompt will be displayed beside the channel

name on the local surveillance image.

Buzzer

Once you check the box here, the buzzer beeps when an alarm

occurred.

Tour

Display the selected video in local monitor window. When alarm
occurs, system can begin one-window tour for the activated record
channel. Please set the tour time in the local end.