IC Realtime 4 Channel PoE Mobile Network Video Recorder User Manual

Page 66

Advertising
background image

57

for the work day/free day setup and the specific work day setup, system just saves the latest

setup. For example, the work day ranges from 8:30-17:30 Monday to Friday, and then you set

the period 7:10-18:00 for Monday. So, the arm period of the Monday ranges from 7:10 to

18:00. Please highlight the corresponding button to enable this function.

PTZ activation: When an alarm occurred, system can activate the PTZ operation such as

preset x.

Anti-dither: Here you can set anti-dither time. The value ranges from 5 to 600s. The

anti-dither time refers to the alarm signal lasts time. It can be seem as the alarm signal

activation stays such as the buzzer, tour, PTZ activation, snapshot, channel record. The stay

time here does not include the latch time. During the alarm process, the alarm signal can

begin an anti-dither time if system detects the local alarm again. The screen prompt, alarm

upload, email and etc will not be activated. For example, if you set the anti-dither time as 10

second, you can see the each activation may last 10s if the local alarm is activated. During

the process, if system detects another local alarm signal at the fifth second, the buzzer, tour,

PTZ

activation, snapshot, record channel will begin another 10s while the screen prompt,

alarm upload, email will not be activated again. After 10s, if system detects another alarm

signal, it can generate an alarm since the anti-dither time is out.

Alarm output: The number here is the device alarm output port. You can select the

corresponding ports(s) so that system can activate the corresponding alarm device(s) when

an alarm occurred.

Latch: When the anti-dither time ended, the channel alarm you select in the alarm output may

last the specified period. The value ranges from 1 to 300 seconds. This function is not for

other alarm activation operations. The latch is still valid even you disable the alarm event

function directly.

Show message: System can pop up a message to alarm you in the local host screen if you

enabled this function.

Alarm upload: System can upload the alarm signal to the network (including alarm centre

and the WEB) if you enabled current function. System only uploads the alarm channel

status. You can go to the WEB and then go to the Alarm interface to set alarm event and

alarm operation. Please go to the Network interface to set alarm centre information.

Send email: System can send out the alarm signal via the email to alert you when alarm

occurs. Once you enable the snap function, system can also send out an image as the

attachment. Please go to the Main Menu->Setting ->Network->Email interface to set.

Record channel: you can select proper channel to record alarm video (Multiple choices).

You need to set alarm record mode as Schedule in Record interface (Main

Menu->Advanced->Record). Please note the manual record has the highest priority.

System record all the time no matter there is an alarm or not if you select Manual mode.

Now you can go to the Schedule interface (Main Menu->Setting->Schedule) to set the

record type, corresponding channel number, week and date. You can select the record

type:Regular/MD/Alarm/MD&Alarm. Please note, you can not select the MD&Alarm and

MD(or Alarm) at the same time.

Now you can go to the Encode interface to select the alarm record and set the encode

parameter (Main Menu->Setting->Encode).

Finally, you can set the alarm input as the local alarm and then select the record channel.

The select channel begins alarm record when an alarm occurred. Please note system

Advertising