1BChapter 2: Camera operation

26

TruVision IP Camera Configuration Manual

• IP Address Conflicted: Conflict in IP address setting.

• Illegal Login: Wrong user ID or password used to login to the cameras.

Figure 13: Exception menu

To define exception alarms:

1. In the

Events

folder, click the

Exception

subfolder to open its window.

2. Under

Exception Type

, select an exception type from the drop-down list.

3. Check the checkbox to select the linkage method.

4. Click

Save

to save changes.

Configuring alarm input and output

To define the external alarm input:

1. In the

Events

folder, click the

Alarm Input

subfolder to open its window.

2. Choose the

Alarm Input No.

and the

Alarm Type

. The alarm type can be NO

(Normally Open) and NC (Normally Closed). Enter a name for the alarm input.

3. Click

Edit

to set the arming schedule for the alarm input. See “To set up

motion detection” for more information.

4. Check the checkbox to select the linkage method.

5. Click

Save

to save changes.

To define alarm output:

1. In the

Events

folder, click the

Alarm Output

subfolder to open its window.

2. Select one alarm output channel from the

Alarm Output

drop-down list. You

can also set a name for the alarm output.