1BChapter 2: Installation

14

TruVision DVR 60 User Manual

Use an RS-485/KTD-83 signal distributor to increase the maximum number of
devices on the bus as well as the total range. Each distributor output provides
another RS-485 bus, extending the output an additional 1200 m. Up to 31
TVR 60s can be connected to each output. See Figure 5 below.

Figure 5: Expanding the system with an RS-485 signal distributor

1. Keypad
2. I/O box

3. RS-485/KTD-83 distributor
4. See section “RS-485 ports” below

Caution

:

Most signal distributors are unidirectional. This means that the signal

only flows from the input towards the outputs. Consequently it is not possible to
connect several keypads.

See section “RS-485 ports” below to configure the RS-485 port communication
settings.

RS-485 ports

There are two RS-485 ports on the rear panel of the TVR 60. See Figure 6 on
page 15 for the serial pin outs.

Dome RS-485:

Term G: Termination of RS-485 bus

G: Ground

A and B: Connect pan, tilt, zoom control of PTZ dome cameras. A = +, B = -

C and D: Not used

Keyb: Connect the keypad.

Advertising