Lamp – Canon MARKLL WUX10 User Manual

Page 49

Advertising
background image

Projector WUX10 MarkII User Commands

- 45 -

Revision History / Date

Changes

Revised by

Approved by

LAMP

Lamp output setting

Format

LAMP=<Lamp output setting parameters:ID>
GET
LAMP / ?LAMP

<Lamp output setting parameters:ID>

NORMAL Normal
SILENT Silent

cooling

Environment

Power

Input

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

VIDEO

HDMI

None

X O X

-

Response

"i:OK" is returned if the parameter was set properly.
For '

GET LAMP

' or '

?LAMP

', current lamp output is returned as

'g:LAMP=<Lamp output setting parameters:ID>'

For details on other responses, refer to the "Error List".

Description

(1) This command is used to set the light quantity of the lamp to "NORMAL" or "SILENT"

(reduced light quantity appropriate for silent cooling).

(2) This command functions in the same way as when "Image adjustment" - "Lamp mode setting"

are selected on the menu.

(3) This sets the currently selected input signal and image mode.
(4) The current lamp output can be acquired using the applicable GET command. ("

GET LAMP

")

Example

Setting

> LAMP=NORMAL

The lamp output is set to “NORMAL”.

< i:OK

Reference

> GET LAMP or ?LAMP

This retrieves the lamp output.

< g:LAMP=SILENT

* Commands are indicated by ">", and responses are indicated by "<".

Advertising