Canon MARKLL WUX10 User Manual

Page 86

Advertising
background image

Projector WUX10 MarkII User Commands

- 82 -

Revision History / Date

Changes

Revised by

Approved by

Item Code TYPE

Error character strings

Error

Remedy

F001 e

SYSTEM (UNKNOWN)

An internal error has occurred.

Resend the command.

F002 e

SYSTEM (AF)

An error occurred at
AUTOSETEXE=FOCUS.

F004 e

SYSTEM (AK)

An error occurred at
AUTOSETEXE=VKS.

11

F005 e

SYSTEM (ASC)

An error occurred at
AUTOSETEXE=SCRN.

Eliminate the cause of the error, and
resend the command.

12 E0XX e

COMMUNICATION_ERROR

A communication protocol violation
has occurred in the projector.

Resend the command.

1008 e


INVALID_SCREEN_ASPECT

Cannot execute command under
current screen aspect ratio setting.

Change the screen aspect ratio
setting.

Cannot execute command with
current input source.

14 200X e

INVALID_SOURCE (****)

Current input source is indicated in
parentheses.

Change the input source.

2010 e

NO_SIGNAL

No input signal.

Supply the input signal.

Cannot execute command with
current input signal.

15

201X e

INVALID_SIGNAL (****)

Current input signal is indicated in
parentheses.

Change the input signal.

16 2020 e

INVALID_IMAGE_MODE

Cannot execute command with
current image mode.

Change the image mode.

17 0801 e

INVALID_VALUE

Numerical parameters are invalid
or outside the specified range.

Set the parameters in the correct
range.

1003 e

IP_NOT_AVAILABLE

IP conversion is not possible.

Switch to the correct input signal.

1004 e


POWER_MANAGEMENT_O
FF

DPON=ON cannot be set when
PMM=OFF.

Use a setting other than PMM=OFF.

1005 e

DIRECT_POWER_ON

PMM=OFF cannot be set when
DPON=ON.

Use the DPON=OFF setting.

Invalid input signal resolution.
Additional information is indicated
in parentheses.

203X e

INVALID_RESOLUTION
(***)

OVER_PANEL_RES: input

signal resolution exceeds panel
resolution.

Switch to an input signal with the
correct resolution.

19 - i

INPUT_NOT_FOUND

Input was not switched since there
is no input signal at
AUTOSETEXE=INPUT.

Notification of status only; no
particular measures needed.

* Error codes are 4-digit hexadecimal strings. X represents any character from 0 to 9 or from A to F.
* Items with lower numbers have a higher priority. (Even when multiple errors have occurred, the error with the highest rank is returned.

However, errors of the same item number are ranked with the same priority.)