Cleaning Intake Filters

The filters should be cleaned or replaced when they become dirty. The frequency will depend on how often and in
what conditions the luminaire is used.

Parts:

10.9816.0788

1 EA

YOKE FAN, AIR FILTER, FOAM

10.9816.0789

1 EA

YOKE FAN, AIR FILTER, ELECTROSTATIC

Tools & Supplies:

#2 Phillips screwdriver
Compressed air

and/or

water

To clean or replace filters:

WARNING:

Remove power from luminaire before performing any maintenance procedures.

Step

1. Remove power from luminaire.

Step

2. Remove pan-side yoke leg cover. (Refer to

"Removing Yoke Leg Covers"

on page 26.)

Step

3. Remove foam filter and electrostatic filter as one unit from yoke leg (Figure 3-6).

Step

4. Clean filters with compressed air and/or by washing with water. Replace as necessary.

Step

5. Re-install components.

Figure 3-6: Removing Air Filters

Note: If the filters do not get clean after multiple attempts, they should be replaced.

Foam Filter

Electrostatic
Filter

Advertising