Replacing light shield – PRG Best Boy Field Service Manual User Manual

Page 51

Advertising
background image

BEST BOY 4000

®

SPOT LUMINAIRE FIELD SERVICE MANUAL

43

Replacing Light Shield

Parts:

10.9816.0029 / 2.37493-R20

1 EA

LENS HOOD, FLEXIBLE

55.0078.1000.0

1 EA

BALL LOKT TIE, 316SS, .310" X .010" X 39.4" COATED (STEEL BAND)

Tools & Supplies:

Tensioning Tool (07.4035.0001.0)
Flat screwdriver
Large wire cutters

WARNING:

Remove power from luminaire before performing any maintenance procedures.

To replace light shield:

Step

1. Remove power from luminaire and allow components to cool for at least 5 minutes.

Step

2. Fold Light Shield to outward position, if applicable. (To access steel band.)

Step

3. Using wire cutters, cut existing steel band to release Light Shield.

Step

4. Install new Light Shield over front ring (Figure 3-18). The notch around the edge of the Light Shield should

fit into the groove of the front ring as shown in Detail A.

Step

5. Wrap new steel band (55.0078.1000.0) around outside edge of Light Shield as shown in Detail B.

Step

6. Feed end of belt through fastener clip, positioning clip near side rail as shown.

Step

7. Be sure band is flush against rubber ridge. Start using Tensioning Tool to tighten band. As band is

tightening, position fastener clip in the middle of the side rail as shown in Detail B.

Step

8. Fully tighten belt, then press silver arm of Tensioning Tool to cut excess.

Advertising