Replacing upper enclosure fan – PRG Best Boy Field Service Manual User Manual

Page 83

Advertising
background image

BEST BOY 4000

®

SPOT LUMINAIRE FIELD SERVICE MANUAL

75

Replacing Upper Enclosure Fan

Parts:

25.9816.0992 / 2.3749A-R05

1 EA

CABLE ASSY, UE CHASSIS FAN

Tools & Supplies:

#2 Phillips screwdriver
11/32" nutdriver
5/32" Allen wrench, T-bar

WARNING:

Remove power from luminaire before performing any maintenance procedures.

To replace the enclosure fan:

Step

1. Remove power from luminaire.

Step

2. Remove Interface/LVS-side Cover. (Refer to

"Removing Upper Enclosure Covers"

on page 27.)

Step

3. At front of Interface/LVS Assembly, remove four 10-32 x 3/4" socket head screws (Figure 3-45).

Step

4. Remove one 10-32 x 3/8" PPB screw that secures ground wire lug.

Step

5. Pull Interface/LVS Assembly out of enclosure enough to disconnect Upper Enclosure Fan Cable.

Step

6. Remove fan by removing two 8-32 hex nuts.

Step

7. Install new Upper Enclosure Fan by doing steps in reverse.

Advertising