66

BEST BOY 4000

®

SPOT LUMINAIRE FIELD SERVICE MANUAL

Step

5. At Thermal Switch, disconnect two wires (Figure 3-38).

Step

6. Remove Thermal Switch Bracket and XYZ Assembly by removing four 8-32 x 1/2" SCBZ screws.

Figure 3-38: Removing XYZ Assembly

YEL

ORN

Thermal Switch Wires

XYZ Assembly

8-32 x 1/2" SCBZ Screw (4)

Thermal Switch Bracket

DETAIL A

Thermal
Switch

Reflector

- Apply Loctite 246