Floor Mounting the Luminaire

The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided
that the mounting surface is flat and sturdy.

Connecting Data and Power

A maximum of 32 luminaires may be connected in any one DMX data link.

Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer
luminaires on a single data link path. Consult your console documentation for more information.

To connect power and data:

Step

1. Connect data cable from console to first luminaire in chain at DATA IN connector

(Figure 2-4).

Step

2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of

remaining luminaires in link.

Step

3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other

devices on the same DMX chain may not function properly without termination.)

Step

4. At each luminaire, connect AC cable from power input source.

Step

5. Dress and secure all cables so that they will not interfere with luminaire head or yoke movement.

Figure 2-4: Connecting Power and Data Cables

Termination

Data In

(from console)

INPUT RATING:

100-240VAC, 50/60 Hz, 10A MAX

DMX IN

DMX THRU

INPUT RATING:

100-240VAC, 50/60 Hz, 10A MAX

DMX IN

DMX THRU

INPUT RATING:

100-240VAC, 50/60 Hz, 10A MAX

DMX IN

DMX THRU

Data Thru

Data Thru

Power In

Power In

Connector

Power In