Programming a Starting Address

The address setting for DMX512 systems is programmed at the Menu Display (refer to

"Menu System"

on page 18 for

more detailed instructions). The luminaire retains its DMX512 address even if power is removed.

Note: Refer to your console operating instructions for specific information regarding its addressing requirements.

Program a DMX512 starting address:

Step

1. Press [Enter] to access top level functions.

Step

2. Press [Up] / [Down] arrows to scroll to

Dmx

menu. Press [Enter].

Step

3. Press [Up] / [Down] arrows to scroll to

Address

menu. Press [Enter] to begin edit mode.

Step

4. Press [Up] / [Down] arrows to enter starting address.

Step

5. Press [Enter] to set.

Figure 2-6: Setting DMX512 Address

Programming Starting Address Without Calibrating

It is possible to bypass the calibration sequence and go directly to the Menu Display programming in order to pre-
program an address setting.

Program starting address without calibrating luminaire:

+

While powering up luminaire, press and hold [Menu]. Program address as in

Programming a Starting Address

above.

Note: The luminaire will require a reset to restore control.

Configuring Lamp Operation and Other Options

The lamp can be turned off or on using the Menu Display. The luminaire can also be configured to power up with the
lamp on or off. For instructions on setting all menu options, refer to

"Menu Functions"

on page 19.