Troubleshooting, Error messages – PRG AutoPar User Manual 2.1 User Manual

Page 36

Advertising
background image

28

AUTOPAR

®

WASH LUMINAIRE USER MANUAL

TROUBLESHOOTING

Error Messages

After calibration, the Menu Display will cycle through any applicable error message(s), one a time until the end of the
list is reached. To review the error messages again, it will be necessary to access them using the Status function.

The following table provides all possible error messages. These errors can be reported for each mechanism (Pan, Tilt,
or Beam), except Enc Fail which does not apply to the Beam mechanism.

To access error messages:

Step

1. Press [Enter] to access top level functions.

Step

2. Press [Up] / [Down] arrows to scroll to

Fixture

menu. Press [Enter].

Step

3. Press [Up] / [Down] arrows to access

Status

. (Display will scroll through any error messages or display

OK

if no errors.)

CAUTION:

If luminaire is operated without yoke leg covers in place, pan problems will occur.

Display

Cause

No Sensor

The active sensor state was not detected during calibration. Mechanism
not moving (off sensor), sensor broken or disconnected.

Sensor On

The sensor was stuck active during calibration. Mechanism not moving
(on sensor), sensor broken or disconnected.

Enc Fail

The encoder was not changing during pan or tilt calibration. Mechanism
not moving, encoder broken or disconnected.