AUTOPAR

®

WASH LUMINAIRE USER MANUAL

37

Photometric Data

AutoPar Luminaire with MSR700 Lamp

* Multiply throw distance by Tn to determine coverage.

**To calculate center beam illuminance (I) at a specific distance (D):

-- if (D) is in feet, (I) is in foot candles

-- if (D) is in meters, (I) is in lux

LENS

CANDELA

(cd) **

BEAM ANGLE

(degrees)

BEAM

(Tn) *

FIELD ANGLE

(degrees)

FIELD

(Tn) *

VNSP

1,625,000

0.087

14°

0.246

NSP

1,155,000

7.5°

0.131

15°

0.263

8-Row Horiz

360,000

18°

0.317

31°

0.555

8-Row Vert

360,000

12°

0.210

23°

0.407

12-Row Horiz

140,000

31°

0.555

50°

0.933

12-Row Vert

140,000

21°

0.371

33°

0.592

11.38"

(289 mm)

(122 mm)

4.80"

(257 mm)

10.12"

I =

cd

D

2